Drop-Flow Fuel Meter [Diaphragm Type]
* Replacement every five years recommended for securing the specific performance.Feature
- Enable to measure 0.1 liter/h
- No pump required because of quite low pressure loss
- No leakage by using magnet coupling for transmitting rotation to numeral counter
- Independent measuring mechanism allows removing debris and air in fuel through drain tap.
[Use Application]
For Measuring Kerosene Consumption on Centralized Kerosene Supply Piping for Multi-dwelling unit
[Precaution]
- Operated by gravity fall. Minimum 30cm head required between the tank (reservoir) and the burner.
- Remove the meter when the pressurized leak test.
- Provide a oil filter before the meter
- Open always the upstream valve to release the raised pressure inside due to temperature rise even while the season not requires the heating equipment.
Specification
| Model No. / Diameter | NDR-6 / 8mm |
|---|---|
| Maximum Working Pressure (MPa) | 0.1 (1kgf/cm²) |
| Maximum Working Temperature (°C) | 50 |
| Deviation (%) | ±1% (Where calculated more than 1 liter) |
| Maximum Cumulative Quantity (L) | 99999.99 |
| Minimum Scale (L) | 0.002 |
| Flow Range (L/h) | 0.1~20 |
| Pressure Loss at Max. Flow (kPa) | 1.0 (102mmH2O) |
| Viscosity (mPa·s) | 2 |
| Fluid | Kerosene |
| Casing | Aluminum Die Cast ADC-12 |
| Weight (kg) | 1.3 |
| Inlet Direction | Left (Right inlet is special order) |
| Connection | Union ( Diameter 28mm / Thread Pitch 18) |
| Connecting Pipe | 15mm diameter SGP Union or 8mm Copper Union |
| Painting Color | Light Grey (Munsell 5Y7.5/1) |
| Model No. | w/Transmitter |
|---|---|
| Output | Voltage Free Change-over Contact, Pulse |
| Pulse Rate | 0.1L/P |
| Terminal Rating | 20W |
| Allowable Max. Voltage | DC30V |
| Allowable Max. Ampere | DC1A |
| Cable | Outer Sheath 6.5mm diameter / 3 wire / 1.5m length |
| Connected Conductor | BK, WT |
External View
[NDR-6]
[GNDR-6]