Diaphragm Gas Meter

Intelligent LPG Meter (Model-SB)

Feature

Shut off by Cumulative, Increased Gas Flow
  • Where the sudden massive flow or unusual cumulative gas consumption detected.
  • Learning function according to the actual consumption enables to set shutdown condition from optimum three levels.
Shut off by Seismic Sensor
  • Where level-5 Japanese seismic load detected during flaming, the built-in seismic sensor shall automatically shut off the valve.
Pressure Observation
  • Built-in pressure sensor observes the gas pressure from regulator outlet to appliances. Where something deviated from normal condition, the indicator alerts. Where the pressure drastically dropped, built-in shutoff valve closed.
Interlock with gas detector located close to the appliance & Power-off alarm
  • Because of commercial use, SB meter is designed on condition of the interlock with the gas detector.
    (Continuous usage time shutdown function is provided with Only SB4 so that no interlock with the gas detector is required while the such function works.
  • Where the power is off i.e., plug pulled out from receptacle, the meter alerts.
Remote Management System (Optional Service)
  • Where the meter connected to the monitoring center via telecommunication line, the periodical meter reading, the remaining gas in cylinder management and user protection management from accidents caused by gas are available.
  • Open-Close operation for shutoff valve is available for SB4 and 6, which contains the bidirectional motor valve, from the monitoring center via telecommunication line.

Precaution

  • Do not disassemble or modify the meter. Those activities may cause malfunction or gas leakage.
  • Installation shall be carried out by the qualified plumber. After the installation, conduct the pressurized leakage test and keep in file.
  • Do not use the meter affected by shock due to drop or something similar situations.

Setting Parameter Table for Shutdown over continuous gas flow time

Group Consumption (kw) Continuous Using Time Adjustment (min)
And Over Less Than Standard Extention-1 Extention-2
1   0.588 No Limitation
2 0.588 5.88 160 720 720
3 5.88 7.00 160 390 600
4 7.00 8.12 160 260 520
5 8.12 10.50 160 160 400
6 10.50 14.00 160 120 300
7 14.00 16.38 100 100 250
8 16.38 19.88 85 85 210
9 19.88 23.94 70 70 180
10 23.94 28.00 60 60 150
11 28.00 32.62 50 50 120
12 32.62 40.88 40 40 100
13-1 40.88 75.60 40 40 75
13-2 75.60 112.00 15 15 15
* This function is available for only SB4 with using learning function.

* Extention-2
Extention-2 can be usable where the gas detector connected.
Where no gas detector connected, standard duration or extention-1 is usable.


Specification

Model No. SBK-4 SBK-6 SBK-10 SBK-16
Measurement Section Direction of Connection Top
Body Male Screw M36 x 2
M36 OD x 2 Nominal Pitch
M56×2 M64×2
Spacing between In & Out 130mm 220mm
Nominal Connection Size NPS 3/4” NPS 1-1/4” NPS 1-1/2”
Direction of Flow Inlet-Left
Max. Operating Flow Rate 4m³/h 6m³/h 10m³/h 16m³/h
Volume of Measurement room 1.74L/Cycle 4L/Cycle
Nominal Operating Pressure Less than 3.24kPa (330mmH2O)
Air Tight Test Pressure 9.8kPa(1.000mmH2O)
Max. Indicating Quantity 9999.999m³ 99999.99m³
Min. Scale 0.2L 2L
Shutdown Section Operating Method Electromagnetic
Shutdown Method Pulse Input >> Close
Restoration Method Pulse Input >> Open Manual
Valve Tightness 4.12kPa(420mmH2O)
Shutdown Indicator LCD & Red LED Push Button
Micro Processor Section Forced Shutdown Excess, Increased Flow / Preset Usage Time / Test/ Gas Detector/Seismic Sensor / Pressure Drop / Remote SD Sensors / Low Battery Voltage
Alert Leakage detection by micro flow or micro press. Drop / Abnormal Setting Press./ Abnormal Block Press. / Shutdown Failure / Low Battery Voltage
Display Security / Shutdown / Alert / Cylinder Reset
Function Setting Telegraphic Setter or Remote Setting from Monitoring Center
Time for safe confirmationafter restoration Approx. 1 min. Approx. 2 min.
Remote Control No. of input & output 5
Terminal Name DT, SG Remote Operator Gas Detector /
External-1and 2
Type of Signals Telegraphic On-Off or Telegraphic On-Off
Power Source Lithium Battery (10 years lifetime for SBK4,6 / 7 years lifetime for SBK10, 16)
Atmospheric Temperature -30°C 〜 +60°C
Standard Painting Color Light Gray (Equivalent to Munsell Color System 5Y 7.5/1)
Weight 5.4kg 9.6kg
Standard no. of unit in one carton 4 1


External View

[SB4/SB6]



[SB10/SB16]





Security Indication on Display

[Meaning of ICON]



1 Registration of Pilot Flame
2 Operational Condition of Automatic Setting Function
Zone of Forced Shutdown due to increased flow
Setting Value of Continuous Flow Observation Zone
3 Gas Flow Image Passing Through Meter
4 Cause of Shutdown and Alert
5 Operational Condition of Shut Off Valve
6 Pressure Observation
7 Gas Leakage Detector Power Loss where Detector has wet contact
8 Observation of Remaining Gas in Cylinder , Rest Signal where Replacement of Cylinder
9 Red Color LED. Flickering where in trouble including shut off valve closed can be reset by pushing.

[Emergency Shutdown Indication]

Description Iconic Indication
Over Excess/ Increased Flow
Over Continuous Using Time
No Leakage Confirmation after Restoration
By Gas Detector
By Seismic Sensor
BY External Signal-1
By Remote Shut Off Valve
By Test Shutdown
From Monitoring Center
By Emergency Shutdown from Monitoring Center
By Low Pressure
By Shutdown Failure
By Low Battery Voltage

[Alert Indication]

Description Iconic Indication
Micro Leakage by Continuous Flow
Low Battery Voltage
Micro Leakage by Pressure Drop
By Abnormal Discharge Pressure
By Abnormal Block Pressure