Product

Hot Water Meter / Cumulative Calorimeter

Flange Connection Type Camulative Calorimeter
(Woltman Type / Model KSE)

  • * To maintain the initial performance, the replacement every five years recommended.
  • * Where a continuous usage, early replacement recommended


Specification

[Specification]

Diameter (mm) 50 ~ 100
Display LCD 7 digit
Minimum Digit ×10MJ
Fluid Temperature Range 0 ~ 100°C (No Freezing Required)
Maximum Nominal Pressure 1MPa
Power Supply AC100V / Lithium Battery

[Volume Calcuration Unit]

Diameter (mm) 50 65 80 100
Minimum Flow Rate (m³/h) 1.5 2 3 5
Maximum Flow Rate (m³/h) 1h/day 15 20 30 50
8h/day 10 15 20 31
12h/day 9 14 17 28
24h/day 7.5 11 15 24


Size / External View

Diameter (mm) 50 65 80 100
Model No. KSE KSE KSE KSE
Total Length (mm) (L) 553 588 623 693
Flow Meter Length (mm) (L1) 280 315 350 420
Temp. Sensor Section Length (mm) (L2) 270 270 270 270
Maximum Height (mm) (H1) 318 358 358 370
Piping Center from Flow Meter Bottom (mm) (H2) 100 110 110 136
Weight (kg) 25 35 40 45
Flange Standard : JIS 10K FF

[Temperature Sensor Section]

Diameter (mm) 50mm ~ 100mm
Type Standard Type-S
Special Type-L




Page Top